//AMB_options_common.dir - will be called once at the beginning to define AMB batch mode options // //--------- mon/con general options ---------- opt cont 1 1 //Base case rating (1-A;2-B;3-C) 2 2 //Contingency rating (1-A;2-B;3-C) 3 100 //Base case rating multipliers 4 100 //Contingency rating multipliers 5 5 //MW cutoff to ignore constraints if cont.flow doesn't changes from the base case more than 6 2 //Rating %% cutoff to ignore if cont.flow changes from the base case is less than 7 1 //Phase shifter model for the base case (0-fixed angle,1-control flow) 8 0 //Adjust branch MW rating based on MVAR flow (DC analysis) 9 0 //Use AMP (=0) or MVA (1) limit to check lines violation in AC mode 10 1 //Use AMP (=0) or MVA (1) limit to check transformer violation in AC mode 11 0.001 //Votlage change cutoff in PU to ignore voltage violations when change from the base case is smaller than 12 15000 //Max number of contingencies 13 35000 //Max number of contingency events 14 40000 //Max number of generation redispatch events 15 10000 //Max number of flowgates 16 0 //Multi-section line modelling (0-ignore;1-honor) 0 0 //--------- AMB Options ---------- option amb report 6 0 0 0 0 // Created AMB LF case format (1-Hour_Ind_YYYY_MM_DD_HH, 0-Hour_Ind) // opt amb general 1 2 // Select Snapshot type(1-Hourly, 2-Daily, 3-Weekly, 4-Monthly) 2 1 // Transaction schedule to include in AMB models (0-ALL,1-Firm Only) // 3 "amb_snapshot.dir" 0 hourly // AMB Hourly calculation options 1 0 // For dynamic scheduling horizon - Hourly adder to midnight / For fixed window - scheduling horizon number hours 2 1 // Hours from the AMB reference time to start creating LF models 3 1 // Use Dynamic Scheduling Horizon until midnight of the current day (0-No, 1-yes) 4 9 // Starting hour to extend scheduling horizon by 24 hours 0 long // AMB long term calculation options 1 1 // AMB Period type (1-FULL_PERIOD, 2-ON_PEAK, 3-OFF_PEAK 2 0.850 // Off-Peak Load Scaling Factor (0-1) 3 7 // First Hour (0-23) for Representative Peak Time Window 4 23 // Last Hour (0-23) for Representative Peak Time Window 5 0 // First Hour (0-23) for Representative Off-Peak Time Window 6 6 // Last Hour (0-23) for Representative Off-Peak Time Window 7 3 // Representative Week Day (1-Monday, 2- Tuesday...) 8 3 // Representative Week for Monthly AFC (1-5) 9 0 // Adjust Daily load in SDX file for load profile if defined (0-no,1-yes) - research one 0 param // AMB parameters and options - do not expect to change often 1 200 // Maximum Hourly snapshots (48-8760) 2 65 // Maximum Daily snapshots (35-1096) 3 10 // Maximum Weekly snapshots (5-104) 4 60 // Maximum Monthly snapshots (18-120) 5 200000 // Maximum number of SDX generator event 6 10000 // Maximum number of SDX branch event 7 10000 // Maximum number of SDX 3Winding outages 8 1 // SDX files use gross load forecast with losses(0-No, 1-yes) 9 1 // Redispatch areas with no load forecast (0-No, 1-yes) 10 5 // Calculation target time zone for (5-EST&EDT, 6-CST&CDT) 11 0 // Exit AMB process on Load forecast error(1-yes, 0-no) 12 1 // TDF Save mode (0-CSV,1-Binary) 13 1 // Method to save TDF, 1- every snapshot, 2-on changes, 3-force at the end) 14 0.0100 // TDF factors change cutoff to create new hourly TDF set 0 0 0